ValuPoint® VP6-1460 IoT Edge Server for SNMP

        ValuPoint® VP6-1460 IoT Edge Server for SNMP

        Control Solutions’ ValuPoint VP6-1460 connects physical I/O (e.g. sensors) to SNMP. In addition, the VP6-1460-SNMP makes any Modbus device accessible  to SNMP. 

        • $1179.00
         
        OR

        Smart I/O and Modbus to SNMP Gateway

        Control Solutions’ ValuPoint VP6-1460 connects physical I/O (e.g. sensors) to SNMP. In addition, the VP6-1460-SNMP makes any Modbus device accessible to SNMP. You can use SNMP Get/Set to query I/O or Modbus points, or set up threshold rules to generate traps in response to physical I/O changes or Modbus changes.

        “I want to receive an SNMP trap when a contact closes.”

        That is what the VP6-1460-SNMP is designed to do - give you access to physical equipment via SNMP. The VP6-1460-SNMP uses threshold rule templates to continuously monitor local sensors or Modbus data and generate SNMP Traps upon sensing of an “alarm” conditions. You can also use SNMP Get to query data at any time. You can use SNMP Set to control outputs or change setpoints.

        Feature Highlights
         • SNMP v1, v2c, v3 Agent
         • User configurable rules for sending SNMP traps/notifications
         • 12 Analog/universal inputs, software selectable types
         • 2 Discrete outputs
         • Modbus RTU Master or Slave
         • Modbus TCP Client and Server
         • Real time scheduler
         • Local user programming with i.CanDrawIt
         • User HTML support for adding custom web pages
         • Configure via secure web pages
         • IPv4 and IPv6 support
         • FCC, CE Mark, UL 916 Listed

        Full product information, data sheet, online user guide, tutorial videos, and more available by clicking here.

        Connect Sensors, Relays, and Modbus Devices to SNMP!

        The physical inputs on the VP6-1460-SNMP can be configured  for analog sensors or discrete sensors, pulse counting, and thermistor input  with internal linearization built in. The inputs are continuously monitored and  data is always real time. 

        The VP6-1460-SNMP will automatically poll whatever Modbus  devices and registers you tell it to, and hold a copy of the data for access by  SNMP. You can provide SNMP access to Modbus coils, discrete inputs, input  registers or holding registers. The VP6-1460-SNMP supports 16, 32, and 64 bit  integer data, 32 and 64 bit floating point, and character strings as a series  of Modbus registers. The Modbus registers you want to make accessible to SNMP  are configured with “read maps” in the BB3-6101.  

        You can also write to Modbus using SNMP Set. Simply  configure a “write map” in the VP6-1460-SNMP to make this connection. SNMP can  send data to Modbus coils or holding registers in the remote Modbus device. 

        The VP6-1460-SNMP can  be Modbus RTU master or slave, and can be Modbus TCP client and server  concurrently. The ValuPoint’s Modbus register map is user configurable.

        The VP6-1460-SNMP supports SNMPv3 as well as SNMPv2 and  SNMPv1. User credentials for SNMPv3 access are entered via the built-in secure  web user interface. 

        The MIB is divided into branches, with the 32-bit integer  branch being the most universal. There are also 64-bit integer, and both 32-bit  and 64-bit floating point branches as well as a character string branch. You  configure the MIB by assigning local Modbus registers to positions in the MIB  branch.

        Traps (or SNMPv3  Notifications) are generated based on rule templates you fill in, and they  reference data found in the MIB branches. In addition to sending the relevant  data with the trap or notification message, the templates include user defined  character string messages.

        VP6-1460-SNMP Features

        • SNMP v1, v2c, v3 Agent
        • User configurable rules for sending SNMP traps/notifications
        • 12 Analog/universal inputs
              • 0-10VDC, thermistor, discrete, dry contact, pulse count
              •  0.1% reference, 12-bit A/D resolution
              • Software selectable input types
              • Non-volatile totalizing count inputs
              (to 2Hz on all channels, to 1kHz on 4 channels)
          • 2 Discrete outputs
              • Form A relay
              • 2A @ 120VAC
              • 2A @ 30VDC• MQTT  Client supports AWS IoT Core, Mosquitto MQTT, ThingsBoard
          • Modbus RTU RS-485 Master or Slave
          • Modbus TCP Client and Server
          • Supported RTU baud rates: 1200, 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
          • Modbus TCP over Ethernet 10/100BaseT
          • Up to 2000 local registers
          • 16, 32, 64-bit integer, 32 or 64-bit IEEE 754 floating point, Mod10
          • ASCII character string support (UTF-8)
          • Supports Modbus “coils”, input registers, holding registers
          • Modbus register mapping configured via web interface
          • Modbus (master) polling interval configurable per point
          • Real time scheduler
          • Local user programming with i.CanDrawIt
          • Configure via web pages, HTTP and/or secure HTTPS
          • Flash file system for XML configuration files, SSL certificates
          • Online help, Quick Help section at bottom of every web page
          • Password protection for web log-on and ftp
          • Field upgradeable firmware upload via ftp
          • DHCP or static IP address, IPv4 and IPv6 support
          • Isolated EIA-485 transceiver for Modbus RTU
          • Powered by 18-30VDC or 24VAC 50/60 Hz Class 2, 0.3A max
         • DIN rail mounting, 100mm H x 70mm W x 60mm D
         • Pluggable screw terminal blocks
         • Operating temperature -40°C to +80°C; Humidity 5% to 90%
         • FCC Class A, CE Mark
         • Listed to UL 916 and (Canadian) C22.2 No. 205-M1983  

        Maximum Object Counts and System Capacities for VP6-1460-SNMP

        VP6-1460-SNMP allows user allocation of memory resources. Memory capacity will not support maximum counts of everything possible, but maximum count limits are set high so that you can allocate resources where you need them.
             
        • Maximum Modbus registers 2000
                                     
        • Maximum MIB Size: 2000 Variables, Integer branch
        • Maximum MIB Size: 1000 Variables, other branches
                                   
        • Maximum Modbus RTU device count 240
        • Modbus RTU read map count 1000
        • Modbus RTU write map count 1000
                                   
        • Maximum Modbus TCP device count 200
        • Modbus TCP Client read mapcount 1000
        • Modbus TCP Client write map count 1000
                                   
        • Maximum weekly scheduler events 1000
        • Maximum on-demand scheduler events 1000